±±¾©³¿»ÔÈÕÉý¹âµç¼¼ÊõÓÐÏÞ¹«Ë¾
 

 

 


¼¤¹âÒ½ÁÆÏµÍ³

 

Selective effect

Comfort and safety

User-friendly software

Compact and ergonomical design

Plug and play system

Mobil, quiet

Low cost and maintenance

Medical laser systems offered today by SOLAR LS are the result of many years of company’s technical experience in development and manufacture of such systems which are already in service at hundreds of our customers.
They accumulate also the recent achievements of thorough scientific research carried out in collaboration with aesthetic and medical centers.
Highly skilled practicing physicians and medical scientists cooperate with SOLAR’s researchers and developers in order to improve and bring to perfection the most advanced medical techniques and innovations which combine top efficiency and extremely careful handling of human body.
Painless and noninvasive treatment which provides excellent aesthetic results and requires no rehabilitation period after operation — this is a real advantage which SOLAR LS offers today for patients.
For practicing physicians our devices are a reliable and intelligent aid which allows to expand their opportunities and grants a number of clinical advantages.
Up­to­date technologies, multifunctionality, simplicity and convenience of use which make comfort both for a physician and for a patient  — all these are the fundamentals of the SOLAR's philosophy integrated in our medical lasers.

AESTHETICS LASER SYSTEMS

The new model DeLight is the result of evolution and development of new laser techniques in medicine. It offers to customers unprecedented flexibility and multifunctionality which have never been attained earlier.
DeLight enables medical personnel to perform three most popular types of treatment in laser cosmetology:

It is worth noting that our laser systems are not of “modular construction” which means that multifunctionality of the device is achieved by expensive mounting of several lasers into one case or by replacing some laser modules by others to provide different applications which usually is not convenient for a customer.
Our devices rather comply with the “all­in­one” principle — the only laser is really used for all three the most popular today cosmetological treatments. This advantage of the device is provided by a plenty of tunable parameters of laser radiation and extremely wide range of their variation.

For each mode of operation physician
can optimize on his own the fluence,
spot size, pulse duration and repetition rate
for the best quality of treatment and then
he can store the suitable set of parameters
in the device memory

Ergonomic design of DeLight ensures mobility and convenience both for a physician and for a patient. Quiet operation and flexible fiber­optical beam delivery system ensure comfortable treatment procedure. All the models can be plugged to the standard single­phase electrical main and
do not require city water connection.

It is highly important that no time­consuming routine procedures are required to switch from one treatment to another and, accordingly, to fundamentally change the laser operation mode. To do this physician just needs to attach one of three smart handpieces, which is appropriate to the treatment chosen.
Such approach provides not only the top immediacy and convenience for the physician but offers also money-saving and flexible system of investments in new equipment.
The customer has an opportunity to order the laser at his choice only for his most urgent application, thus, having minimized his expenses.

DeLight can be supplied with an adjustable
spot size handpiece integrated with
a skin cooler. Such a design provides
maximum convenience for the physician
and minimizes skin injury caused by
epidermal heating
To increase the patient's comfort during
treatment, DeLight can come upon your choice either with a compact and efficient
Peltier skin cooler or with a high­power
air skin cooler

Later on, if physician wishes to expand his clinical opportunities, he just needs to purchase the smart handpiece, which is appropriate to the type of treatment desired, and to attach it to the laser body.

HAIR REMOVAL

Unlike radiation of other types of laser and lamp epilators, the laser beam of DeLight at wavelength 1064nm is less absorbed by melanin of skin and is innocuous for it. Low absorption allows this radiation to penetrate into skin as deep as 4mm and to reach hair bulbs at different depths practically regardless of skin’s complexion.

That is why DeLight can be used for treatment of patients with skin of any type according to Fitzpatrick’s classification and any depth of follicles’ bedding and its use has no limitations imposed by racial peculiarities.

The possibility to adjust pulse duration from 7 up to 50ms and to control the shape of pulses with microprocessor by setting the combinations of their duration, form and repetition rate gives additional benefits to the doctor since it allows to achieve selective destruction of hair follicles of any type with a minimal heating of superficial skin layers.

High output energy ensures the fluence which is appropriate for hair removal at a spot size of 13mm that can’t be attained with the majority of other laser epilators.

Processing per pulse such an extremely large area not only increases the speed of operation, but also considerably reduces the cost of treatment.

VASCULAR LESION TREATMENT

Laser pulse width of DeLight can be adjusted by physician to match termal relaxation time of the selected vessel, allowing the laser radiation to heat the target long enough to produce significant termodamage, but short enough to prevent heat dissipation to the surrounding tissue.

DeLight ensures successful treatment, practically painless and harmless for a skin, of undesirable vascular formations not only in the facial area but also for rather large veins up to 5 mm in diameter on legs.

That is why DeLight gives an opportunity to successfully cure the widest circle of patients who would prefer to substitute long and painful operations of sclerotherapy for fast, safe and effective laser therapy, regardless of season and complexion.

NONINVASIVE SKIN REJUVINATION AND TONING

The optimum matching of pulse duration and power parameters of DeLight with a thermal relaxation time of microvessels allows to achive effective smoothing of the most diverse types of skin due to a growth and tightening of collagen. Smoothing of small and moderately large wrinkles is accompanied by significant improvement of skin’s tone and texture that increases considerably cosmetologic effect of treatment. The operation does not require anesthesia and cooling of skin, and also patient needs no special subsequent care and recovery time.

That is why a technique of photo­rejuvenation provided by DeLight, in contrast to ablative techniques typical for the use of CO2, erbium or holmium lasers, perfectly suits the needs and expectations of active middle­aged patients who wish to improve their appearance without an interruption in everyday’s activity, degree of suntan and phototype of skin being of no importance.

SPECIFICATIONS:

Nd:YAG LASER SYSTEM FOR AESTHETICS
DeLight

Laser type

Variable pulse width Nd:YAG laser

Wavelength, nm

1064

Max output energy, J

80

Application

Hair removal

Vascular lesion treatment

Skin rejuvination

Pulse width, msec

10...50

10...50

0.3

Max fluence, J/cm2

100

300

18

Spot size, mm

7, 10, 13

5

5

Repetition rate

single shot,
0.5 to 2 Hz

single shot,
0.5 to 2 Hz

single shot,
1 to 10 Hz

Beam delivery system

ø800µm x 2.5m optical fiber

Aiming beam

red laser diode

Control panel

LCD screen, touch panel;
fluence, pulse width, spot size, repetition rate set up;
real time output monitoring

Calibration

internal calibration port

Accessories

Peltier skin cooler;
air skin cooler;
integrated with handpiece Peltier or air skin cooler

Cooling

self-contained water-air cooling system

Environmental
conditions

(15…27)°C ambient temperature

Dimensions (H x W x D), mm

775 x 330 x 650

Power requirements

220V ±10%, single phase, 50/60 Hz, < 9A

Weight, kg

70

Specifications are subject to change without notice.

You can download specifications in PDF format

ALEXANDRITE LASER SYSTEM FOR AESTHETICS
Model A30

Laser type
Variable pulse width Alexandrite laser
Application
Hair removal
Wavelength, nm
755
Pulse width, msec
10...50
Max output energy, J
30
Spot size, mm
7, 10, 13
Max fluence, J/cm2 80
Repetition rate
single shot; (0.5…2)Hz
Beam delivery system
ø800µm x 2.5m optical fiber
Aiming beam
red laser diode
Control panel
LCD screen, touch panel;
fluence, pulse width, spot size, repetition rate set up;
real time output monitoring
Calibration
internal calibration port
Accessories
Peltier skin cooler;
air skin cooler;
integrated with handpiece Peltier or air skin cooler
Cooling
self-contained water-air cooling system
Environmental conditions
(15…27)°C ambient temperature
Dimensions (H x W x D), mm
775 x 330 x 650
Power requirements
220V ±10%, single phase, 50/60 Hz, < 9A
Weight, kg
70

Specifications are subject to change without notice.

You can download specifications in PDF format

RUBY LASER
FOR TREATMENT OF PIGMENTED LESION
Model R15

APPLICATIONS

  • Nevus Cell Nevus
  • Spilus Nevus
  • Becker's Nevus
  • Senide Pigmented Freckle
  • Freckles
  • Seborrheic Keratosis
  • Lentigo

Ruby laser beam is an optimal choice for treatment of pigmented lesion originating in melanin. The reason is that ruby laser beam undergoes minimal absorption in collagen and so it influences melanin selectively leaving all other tissues intact.

The diagram shows difference in absorbtion of R15 laser beam (694nm)
by collagen that forms skin tissue and melanin of birthmark

• In order to preserve high lasing efficiency, conventional ruby lasers operate at the temperature of laser head not higher than 20°C. At this temperature there is a great risk of moisture condensation on optical parts which can lead to their damage. This fundamental drawback of ruby lasers is completely eliminated in the R15 Model. Unique design features of the laser allow to provide high­efficient laser output at laser head temperature of about 30°C. As a result, R15 shows the highest reliability and powerful output from a compact unit.

• The laser parameters are easily controlled via a modern display which offers a physician maximum comfort during the treatment.

• Monitoring and control system ensures that the actual output energy value corresponds to the value preset on the display irrespective of the operation time and temperature that ensures the safe treatment for a patient.

MediLight R15

SPECIFICATIONS

RUBY LASER SYSTEM FOR AESTHETICS
Model R15

Laser type
Ruby laser
Application
Pigmented lesion treatment
Wavelength, nm
694
Pulse width, µsec
450
Max output energy, J
6
Spot size, mm
5
Max fluence, J/cm2 30
Repetition rate
single shot; 1Hz
Beam delivery system
ø1mm x 2.5m optical fiber
Aiming beam
red laser diode
Control panel
LCD screen, touch panel;
fluence, repetition rate set up;
real time output monitoring
Calibration
internal calibration port
Accessories
Peltier skin cooler;
air skin cooler;
integrated with handpiece Peltier or air skin cooler
Cooling
chiller
Environmental conditions
(15…27)°C ambient temperature
Dimensions (H x W x D), mm
1000 x 510 x 630
Power requirements
220V ±10%, single phase, 50/60 Hz, £ 7A
100V ±10%, single phase, 50/60 Hz, £15A
Weight, kg
115

Specifications are subject to change without notice.

You can download specifications in PDF format

UNIVERSAL Nd:YAG LASER FOR SURGERY
Model J100

APPLICATIONS

  • Urology
  • Gynecology
  • General Surgery
  • Dermatology
  • Plastic Surgery
  • Gastroenterology
  • Pulmonary

Laser application in surgery allows not only to perform unique and delicate operations with minimal traumatism of tissue, but also ensures effective coagulation.

The J100 laser delivers the power you need for a variety of surgical procedures with the precision you wish for the optimal tissue effect. It is the system that can operate either in continuous wave or various pulse modes at your choice. Pulse mode provides protection from tissue overheating and extends optical fiber lifetime.

Ergonomical control panel design provides easy and comfortable laser operation.

The doctor can store his own treatment parameters by means of up to 8 settings for different applications.

For your applications the laser provides up to 100W continuous power and does not require either city water for cooling or any other special conditions. You only have to connect it to the single-phase electrical main.

MediLight J100

The J100 laser delivers the power you need for a variety of surgical procedures with the precision you wish for the optimal tissue effect. It is the system that can operate either in continuous wave or various pulse modes at your choice. Pulse mode provides protection from tissue overheating and extends optical fiber lifetime.
Ergonomical control panel design provides easy and comfortable laser operation.

The doctor can store his own treatment parameters by means of up to 8 settings for different applications.

For your applications the laser provides up to 100W continuous power and does not require either city water for cooling or any other special conditions. You only have to connect it to the single-phase electrical main.

SPECIFICATIONS

UNIVERSAL Nd:YAG LASER FOR SURGERY
Model J100

Laser type
CW Nd:YAG laser
Output modes
continuous / repeated pulses / single pulse
Output power (CW mode), W
1...100
Output power stability, %
±5
Repeated pulse mode, sec
pulse width: 0.02…60
interval: 0.02…10
Beam delivery system
gas cooled optical fiber, SMA905 connector
Aiming beam
532nm laser module
Control panel
8 programs;
monitoring of output power, pulse duration,
repetition interval; indication of cumulative energy, applied to tissue;
error monitoring
Power consumption,
(single phase, 220V ±10%, 50/60Hz), kVA (no more than)
4
Cooling
self-contained water-air cooling system
Environmental conditions
(15…27)°C ambient temperature
Dimensions (H x W x D), mm
920 x 495 x 620
Weight, kg
76

Specifications are subject to change without notice.

You can download specifications in PDF format

 

CUSTOM LASER SYSTEMS AVAILABLE UPON YOUR REQUEST

1. Photodynamic Therapy Laser Systems. Quasi-CW Red (670nm) Laser up to 5W output with optical fiber delivery system.

2. Laser System for Hemangiomas and Portwine Stains Treatment. Quasi-CW Green (540nm) Laser up to 10W output with optical fiber delivery system. Please refer to our representatives to obtain more detailed information.

 

 

¡¡¡¡¡¡¡¡µØÖ·£º±±¾©Êг¯ÑôÇøÍû¾©Î÷Ô°222ºÅÐÇÔ´¹ú¼ÊB×ù1601ÊÒ Óʱࣺ100102
µç»°£º010-84718151 84718152 ´«Õ棺010-64740680
Email: sales@bjlaser.com; zzw512@vip.sina.com
©2005,Beijing Sunrise Optoelectronics Co.,Ltd.